About Us Contact Us
 
 
   
Critical Care - ICU Ventilator - Ventilator
 
Sirio Baby 100
 
Features :
 

 

Appliance Emergency / First-Aid / Transport

Patients Children / Newborns / Prematures
Type of ventilation IPPV Volumetric - IPPV Pressometric
Control modalities Electronic
Flow generation Venturi system with adjustable mixer
Gas feeding Oxygen - the pressure should be included between 280 kPa and 600 kPa
(2,8 – 6 bar).
Modes of ventilation IPPV / CPAP / IMV / Manual Breath
Breathing rate From 1 to 100 bpm (on display)
Mean pressure Shown on display
Inspiratory time From 0.2 to 3 sec
Expiratory time From 0.4 to 30 sec
Low pressure alarm Adjustable from 0 to 25 cmH2O
High pressure alarm Adjustable from 0 to 60 cmH2O
PEEP/CPAP Adjustable from 0 to 20 cmH2O
Pressure limit Adjustable from 0 to 60 cmH2O
Adjustable mixer Adjustable from 45 to 100%
Flow trend Constant
Inspiratory flow 8.5 l/min constant
Flow-by In IMV and CPAP = 8.5 l/min constant
In IPPV = 0.5 l/min max.
Bronchomanometer Mechanic from -20 to 80 cmH2O
Alarms Low and High airways pressure / Apnoea / Low battery / Gas supply / Power
failure
Electric power supply 100 / 240Vac – 12Vdc
Power consumption 0,02 A at 220Vac
0,4 A at 12Vdc
Sirio BABY100_te_rev5.doc 2 / 2
Power 4.5 W
Battery operation With internal Pb battery:
• Autonomy of about 45 min - on worst conditions (max consume)
• Autonomy of about 1,30 h - on average conditions (normal use)
Recharging Time Battery to 100% / about 8 hours
Safety Mechanic limit of airways pressure to 65 cmH2O
User's interface Mechanic bronchomanometer / Battery level LED on battery charger / Alarm
LED / Display / Knob keys
External connections Electric: 12Vdc power supply / from 100 to 240Vac power supply
Gas: Oxygen
Dimensions (W x H x D) 31 x 19 x 18 cm (with handle)
Weight 4,3 Kg
Standard accessories
(supplied)
• User’s manual
• O2 supply hose (code G60005100)
• Silicone patient circuit with expiratory valve (code 102641/SLU)
• Feeder (code G30146100)
• 12 Vdc vehicular power cable (code G30147100)
Conformity to Norms EN 1281-1, IEC 601-1, IEC 601-1-2, Dir.ve 93/42 EEC, IEC 601-1-4, EN
794-3
Class and type
according to IEC 601-1
Class 1 Type B
Class according to 93/42
EEC Directive
Class IIb
Environmental
Conditions
Temperature from -10 to 40 °C
Relative humidity from 15 to 95 % non condensing
Atmospheric pressure from 70 to 110 kPa.
 
 
Authorised Sales & Service Dealer
  • Works with Ultrasound
  • C-Arm
  • Lithiotripter
  • OPG
  • CR Systems
  • ICU Monitoring Systems
  • X-Ray Machines
  • Surgical Instruments
  • Darkroom
  • Accessories
  • High Voltage Transformers
  • X-ray Machine & Spares
 
Call +91-9810024291
 
Copyright © 2010 AA Medical Systems. All Rights Reserved.