Critical Care - Pulse-Oximeter-Patient-Monitoring
 
PMC 3000
 
Features :


 

Patient Range

Adult, Pediatric and neonatal

 

Performance Specification

Display                                      : 12.1” color active matrix TFT

Resolution                                   : 800x600

Trace                                          : 7waveforms

Sweep Speed                             :12.5,25,50mm/s

                                                    Alarm indicator light

                                                    Power indicator light

                                                   Audio Indicators for QRS beep and alarm sound

Interface                                     : Networking

Battery                                       : Rechargeable

Trend time                                 : 1~72 hours

Alarm                                        : 3-level audible and visual alarm

Recorder (optional)                    : Built-in, thermal array,3channels

Record Width                            : 40mm (record paper 50mm)

Record Speed                            : 25mm/s, 50mm/s

 

ECG

Lead Type                                  : 5-lead

Input                                          : 5-lead(RA; LA; RL; LL; V)

Lead Selection                            : 5-Lead; I; II; III

ECG Waveform                         : 1 channel

Gain Selection                            : x0.5,x1,x2,auto

Sweep Speed                             : 12.5mm/, 25mm/s

Heart rate range                         : 25~20BPM

Accuracy                                    : 1BPM

                                                    Anti-electrosurgical interference and defibrillation

 

Standard Configuration

ECG, RESP,NIBP,TEMP,SPO2

 

EtCO2 Micro Stream Latest Technology Modular Cassete.

 

OPTIONS:

IBP,FHR Module, Thermal, Recorder Li-ion Battery, Wall Mounting, Trolley

 

CMRR                                     : Diagnostic mode:>60db

                                        Monitor mode:>60db

S-T detection                           : YES

Measurement range                 : -20mV-2.0mV

Arrhymia analysis                    :YES

Alarm                                      :YES, audible and visual alarm, alarm events            

                                                recallable

 

Respiration

Method                                    : RA-LL impedance

Measurement Range                 : 20~250BrPM

Resolution                                : 1BrPM

Accuracy                                  : 2% or 2BrPM, whichever is greater

Apnea Alarm                            : YES, and apnea delay:10~40seconds

  

NIBP

Method                                    : Oscillometric

Operation Modes                    : Manual /Automatic

Measurement Unit                   : mmHg/kPa selectable

Measurement Type                  : Systolic pressure Diastolic pressure and Mean          Pressure  

Measurement Range                : Systolic Pressure:50-24 mmHg

                                                  Diastolic Pressure:25~180mmHg

                                                  Mean Pressure:30~200mmHg

Over-pressure Protection          : YES

Resolution                                : 1mmHg

Alarm                                        : Systolic, Diastolic and Mean

 

Temperature

Scale                                        : C and F Selectable

Measurement Range                   : 27’C ~45C

Resolution                                : 0.1 or

Channel                                    : 1 Channel

 

SPO2

Range                                      : 0~100%

Accuracy                                 : 70% ~100%(+2%)

0%~69%                                  : unspecified

 

Pulse Rate

Range                                      : 20~254BPM

Accuracy                                 : 3 BPM

  Safety                                                                                    

Meet requirement of IEC60601-1                                           

 

Dimension and weight                                                           

Dimension                                335x270x200(mm)     

Weight                                       5.4 kg                

 

Power Supply                                                     

Power Source                             : AC mains power or Internal battery power    

Power Requirements                   : AC 220V(10%)                                               

Line Frequency                            : 50 Hz (+ 1Hz)                                        

Consumption                               : 60 W      

                                                         

Battery Power    

The maximum number of installed battery:1                

Operating time                             : 180 minutes under the normal use and full

                                             charge                                    

Operation Environment

Temperature                              :10C to 30’C (50F to 86F)

Humidity                                    :15% to 70%, non-condensing

 
Authorised Sales & Service Dealer
  • Works with Ultrasound
  • C-Arm
  • Lithiotripter
  • OPG
  • CR Systems
  • ICU Monitoring Systems
  • X-Ray Machines
  • Surgical Instruments
  • Darkroom
  • Accessories
  • High Voltage Transformers
  • X-ray Machine & Spares
 
Call +91-9810024291
 
Copyright © 2010 AA Medical Systems. All Rights Reserved.